Zeiss TIRF
Total Internal Reflection (TIRF) microscopy is a technique, which allows imaging of fluorophores near of the basal cell membrane with high resolution in Z-axis. Approximately 70-150 nm -axis resolution can be achieved, while in common confocal microscopy the limit is approximately 600nm.
TIRF is designed for cell membrane studies, such as endosytosis and integrin trafficking. However, it is very suitable for all kinds of sensitive wide field microscopy, due to high quality objectives and sensitive cameras.
Our TIRF has two different cameras dedicated to different applications: a very sensitive emccd camera with a 512×512 chip, and a sensitive and fast high resolution sCMOS camera. The microscope is equipped with incubation elements, motorized stage and Zeiss Definite Focus drift correction device.
Reservation System: Zeiss TIRF
Location: BioCity, 2nd floor, room 2209
TIRF is designed for cell membrane studies, such as endosytosis and integrin trafficking. However, it is very suitable for all kinds of sensitive wide field microscopy, due to high quality objectives and sensitive cameras.
Our TIRF has two different cameras dedicated to different applications: a very sensitive emccd camera with a 512×512 chip, and a sensitive and fast high resolution sCMOS camera. The microscope is equipped with incubation elements, motorized stage and Zeiss Definite Focus drift correction device.
Reservation System: Zeiss TIRF
Location: BioCity, 2nd floor, room 2209
2.5x Zeiss EC Epilan-Neofluar
• Numerical Aperture: 0.06
• Working Distance: 15.1 mm
• Immersion: Without immersion
10x Zeiss EC Epilan-Neofluar
• Numerical Aperture: 0.3
• Working Distance: 5.2 mm
• Immersion: Without immersion
20x Zeiss Plan-Apochromat
• Numerical Aperture: 0.45
• Working Distance: 8.2-6.9 mm
• Immersion: Without immersion
• Numerical Aperture: 0.06
• Working Distance: 15.1 mm
• Immersion: Without immersion
10x Zeiss EC Epilan-Neofluar
• Numerical Aperture: 0.3
• Working Distance: 5.2 mm
• Immersion: Without immersion
20x Zeiss Plan-Apochromat
• Numerical Aperture: 0.45
• Working Distance: 8.2-6.9 mm
• Immersion: Without immersion
63x Zeiss α Plan-Apochromat
• Numerical Aperture: 1.46
• Working Distance: 0.55 mm
• Immersion: Oil
100x Zeiss α Plan-Apochromat
• Numerical Aperture: 1.46
• Working Distance: 0.11 mm
• Immersion: Oil
• Numerical Aperture: 1.46
• Working Distance: 0.55 mm
• Immersion: Oil
100x Zeiss α Plan-Apochromat
• Numerical Aperture: 1.46
• Working Distance: 0.11 mm
• Immersion: Oil
- 488nm
- 561nm
- 639nm
GFP - filter set 38 HE
Excitation: BP 470/40nm
Emission: BP 525/50nm
DsRed - filter set 43 HE
Excitation: BP 550/25nm
Emission: BP 605/70nm
CFP/GFP/DsRed - filter set 76 HE
Excitation: TBP 406 + 489 + 561nm
Emission: TBP 459 + 525 + 608nm
GFP/mRFP/Alexa633 - filter set 77 HE
Excitation: TBP 483 + 564 + 642nm
Emission: TBP 526 + 601 + 688
- Hamamatsu EMCCD c9100-13
- 512x512 pixels
- Hamamatsu ORCA Flash4 CMOS
- 2048x2048 pixels
- Definite Focus
- Heated incubator
- Heated sample holder